(0)

AQ F213 Feeder Protection Relay

AQ F213-AQ F213 Feeder Protection Relay

Sipariş No : AQ F213

AQ F213 offers a modular feeder protection and control solution for applications requiring both current and voltage based protections along with complete measurements of up to class 0.2S accuracy for power and energy. Up to three optional I/O or communication cards are available for more comphrehensive monitoring and control applications. The AQ F213 communicates using various protocols including IEC 61850 substation communication standard.

AQ F213 Feeder Protection Relay


Protection Function ANSI     Protection Function ANSI
Three-phase overcurrent protection INST,DT or IDMT - I> ... I>>>> 50/51     Undervoltage protection DT or IDMT - U 27
Directional three-phase overcurrent protection INST,DT or IDMT - IDir> ... IDir>>>> 67     Residual voltage protection DT or IDMT - U0>...U0>>>> 59N
Residual overcurrent protection INST, DT or IDMT - I0> ... I0>>>> 50/51N     Over/under/reverse power protection DT or IDMT - P>/P...P>>>>/P 32
Directional (sensitive) residual overcurrent protection INST, DT or IDMT - I0Dir> ... I0Dir>>>> 67N     Frequency protection - f>/f>>>/f<<<< 81U/O
Harmonic overcurrent protection / inrush blocking INST, DT or IDMT - Ixh > ... Ixh >>>> 50/51h/68h     Rate of change of frequency protection - df/dt 81R
Cold load pick-up block – CLPU 68     Auto-reclose - 0 -> 1 (5 shots) 79
Current unbalance / broken conductor protection INST, DT or IDMT - I2 (I/I1)>...I2 (I/I1)>>>> 46/46R/46L     Fuse failure protection – VTS 60
Low or high-impedance restricted earth-fault / cable end differential protection - I0d> 87N     CT supervision- CTS  
Cable thermal overload protection - T > 49F     Switch onto fault logic - SOTF  
Overvoltage protection DT or IDMT - U>...U>>>> 59     Breaker failure protection - CBFP 50BF/52BF
  
  • Large customizable HMI with configurable Mimic diagram
  • 16 freely configurable multi-colour LEDs with user description selectable texts
  • Measurement accuracy of up to class 0.2S (Optional with Voltage Inputs)
  • 6 Inputs (8/16/24 Optional) - 6 Outputs (5/10/15 Optional)
  • Up to 15000 events in permanent flash memory, 60MB memory for disturbance records and user files
  • IEC 61850, HSR, PRP, IEC 101,IEC 103, IEC 104, Modbus, DNP 3.0, SPA
  • NTP, Precision Time Protocol (PTP) according to IEEE 1588
  • Sub-cycle instantaneous trip times
  • Fast integrated arc protection
  • Frequency independent protection at 6…75Hz

Photos

Videos

Files

Save ×
Save ×

Write To Us

Dear Customer,

We really care about your suggestions.

You can freely post your opinions and complaints if any :) about our company, our products and services.

Our quality department will detailly evaluate your posts and will inform you as soon as possible.

Many thanks for your kind interest.

Best Regards.

RELKO ENERJI


(*)
(*)
(*)
(*)
×

×